Isolation and identification of Legionella spp. from nonhospital facilities: a preliminary one-year surveillance study in the urban area of Pesaro-Urbino (Central Italy)
Keywords:
Legionella spp., isolation, survey study, Central ItalyAbstract
Background. Legionella is considered one of the most important causes of potentially preventable morbidity and mortality. These microorganisms are ubiquitous, but incomplete information is available on the geographic distribution of Legionella species in our region.
Study design. For the mentioned reasons, in this work the distribution of Legionella spp. in non-hospital facilities of the urban area of Pesaro-Urbino (Central Italy), including public fountains, residential buildings, public and private offices and retirement homes, was investigated.
Methods. A total of 298 water samples were collected from the different facilities and subjected to standard Legionella isolation and identification protocols.
Results. As reported, 17.8% of the collected water samples resulted positive for Legionella spp. (28.6% from retirement homes, 21.3% from residential buildings, 15.3% from private and public offices). The highest percentage of positive samples (14.4%) was found in hot water from retirements homes (58.8%) and residential buildings (31.8%); the most frequent isolated serogroups were L. pneumophila 2-14 (71.7%).
Conclusions. This work is the first describing the distribution of Legionella spp. in non-hospital facilities in the province of Pesaro-Urbino, and highlights a condition of potential risk for susceptible categories. From our data, we can point that a regular and constant control to prevent microbiological risk from legionellosis, particularly in facilities housing the elderly, is recommended.
References
1. D’Alessandro D, Fabiani M, Cerquetani F, Orsi GB. Trend of Legionella colonization in hospital water supply. Ann Ig 2015; 27(2): 460-6. doi: 10.7416/ai.2015.2032.
2. Collins S, Stevenson D, Bennett A, Walker J. Occurrence of Legionella in UK household showers. Int J Hyg Environ Health 2017; 220(2 Pt B): 401-6. doi: 10.1016/j.ijheh.2016.12.001.
3. Ferranti G, Marchesi I, Favale M, Borella P, Bargellini A. Aetiology, source and prevention of waterborne healthcare-associated infections: a review. J Med Microbiol 2014; 63(Pt 10): 124759. doi: 10.1099/jmm.0.075713-0.
4. World Health Organization (WHO). Guidelines for Drinking-water Quality: Fourth Edition, 2017. Incorporating the First Addendum. Available on: https://www.who.int/water_sanitation_health/ publications/drinking-water-quality-guidelines4-including-1st-addendum/en/http://apps.who. int/iris/ [Last accessed: 2021, Mar 15].
5. Rogers J, Dowsett AB, Dennis PJ, Lee JV, Keevil CW. Influence of temperature and plumbing material selection on biofilm formation and growth of Legionella pneumophila in a model potable water system containing complex microbial flora. Appl Environ Microbiol 1994; 60(5): 1585-92. doi: 10.1128/AEM.60.5.15851592.1994.
6. Montagna MT, Cristina ML, De Giglio O, et al. Serological and molecular identification of Legionella spp. isolated from water and surrounding air samples in Italian hospitals. Environ Res 2016; 46: 47-50. https://doi.org/10.1016/j. envres.2015.12.015.
7. De Filippis P, Mozzetti C, Messina A, D’Alò GL. Prevalence of Legionella in retirement homes and group homes water distribution systems. Sci Total Environ 2018; 643: 715-24. doi: 10.1016/j.
scitotenv.2018.06.216.
8. Hamilton KA, Prussin AJ, Ahmed W, Haas CN. Outbreaks of Legionnaires’ Disease and Pontiac Fever 2006-2017. Curr Environ Health Rep 2018; 5(2): 263-71. doi: 10.1007/s40572-018-0201-4
9. Herwaldt LA, Marra AR. Legionella: a reemerging pathogen. Curr Opin Infect Dis 2018; 31(4): 32533. doi: 10.1097/QCO.0000000000000468.
10. Phin N, Parry-Ford F, Harrison T, et al. Epidemiology and clinical management of Legionnaires’ disease. Lancet Infect Dis 2014; 14(10): 101121. doi: 10.1016/S1473-3099(14)70713-3.
11. Totaro M, Valentini P, Costa AL, et al Presence of Legionella spp. in hot water networks of different Ita.lian residential buildings: a three-year survey. Int J Environ Res Public Health 2017; 14(11): 1296. doi: 10.3390/ijerph14111296.
12. Prussin AJ, Schwake DO, Marr LC. Ten questions concerning the aerosolization and transmission of Legionella in the built environment.
Build Environ 2017; 123: 684-95. doi: 10.1016/j. buildenv.2017.06.024.
13. European Centre for Disease Prevention and Control (ECDC). Annual Epidemiological Report on Communicable Diseases in Europe, 2017. Surveillance atlas of infectious diseases [Internet]. Stockholm: ECDC, [cited 30 Jan 2018]. Available on: http://atlas.ecdc.europa.eu [Last accessed: 2021, Mar 15]
14. Italian National institute of health. Guidelines for Prevention and Control of Legionellosis. Italian Health Ministry. Rome, Italy, 2015.
Available on: http://www.salute.gov.it/imgs/ C_17_pubblicazioni_2362_allegato.pdf [Last accessed: 2021, Mar 15].
15. International Organization for Standardization (ISO). ISO 19458 Water Quality – Sampling for Microbiological Analysis. Geneva, Switzerland, 2006.
16. Bonadonna L, Ottaviani M. Analytical methods for water for human consumption in accordance with Legislative Decree 31/2001. Microbiological methods. Rome: ISS, 2001 (Rapporti ISTISAN 07/5 2001).
17. DR0800 booklet, revised 2016. Legionella Latex Test. OXOID Limited, Wade Road, Basingstoke, Hampshire, RG24 8PW, UK. Available on: http:// www.oxoid.com/UK/blue/prod_detail/prod_detail.asp?pr=DR0802&cat=&c=UK&lang=EN
[Last accessed: 2021, Mar 15].
18. Garrison LE, Kunz JM, Cooley LA, et al. Vital signs: Deficiencies in environmental control identified in outbreaks of Legionnaires’ disease - North America, 2000–2014. MMWR. Morb Mortal Wkly Rep 2016; 65(22): 576-84. doi: 10.15585/mmwr.mm6522e1.
19. Montagna MT, De Giglio O, Cristina ML, et al. Evaluation of Legionella air contamination in healthcare facilities by different sampling methods: an Italian multicenter study. Int J Environ Res Public Health 2017; 14(7): 670. doi: 10.3390/ijerph14070670.
20. Montagna MT, De Giglio O, Napoli C, et al. Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy. Environ Res 2018; 166: 55-60. https://doi. org/10.1016/j.envres.2018.05.030.
21. Napoli C, Fasano F, Iatta R, Barbuti G, Cuna T, Montagna MT. Legionella spp. and legionellosis in southeastern Italy: disease epidemiology and environmental surveillance in community and health care facilities. BMC Public Health 2010; 10: 660. doi: 10.1186/1471-2458-10-660. 23.
22. Baggiani A, Casini B, Totaro M, et al. Colonization by Legionella spp. of water networks in residential buildings of the Province of Pisa, Italy. Ann Ig 2015; 27(5): 718-25. doi: 10.7416/ ai.2015.2064.
23. Borella P, Montagna MT, Romano-Spica V, Stampi S, Stancanelli G, Triassi M, et a. Legionella infection risk from domestic hot water. Emerg Infect Dis 2004; 10(3): 457-64. doi: 10.3201/eid1003.020707.
24. De Filippis P, Mozzetti C, Amicosante M, et al. Occurrence of Legionella in showers at recreational facilities. J Water Health 2017; 15(3):
402-9. doi: 10.2166/wh.2017.296.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Transfer of Copyright and Permission to Reproduce Parts of Published Papers.
Authors retain the copyright for their published work. No formal permission will be required to reproduce parts (tables or illustrations) of published papers, provided the source is quoted appropriately and reproduction has no commercial intent. Reproductions with commercial intent will require written permission and payment of royalties.